Victor Regulators Drop & Creep Test Chart

  SR700A
VTS700A
VTS450A
VTS250A
VGT460A
SR450A
SR350A
SR250A
SR700B
VTS700B
VTS450B
VTS250B,C
VGS350
VGS361
VGS360
SR450B
SR350C
SR250B,C
SR700D
VTS700D
VTS450D
VTS250D
VGT450
SR450D
SR350D
SR250D
SR700E
VTS700E
VTS450E
SR450E
VGS460 VGS450
Test gun orifice size. #52
(.0635")
#52
(.0635")
#52
(.0635")
#52
(.0635")
#52
(.0635")
#52
(.0635")
Set regulator to ___ PSIG. 5 10 20 50 5 20
Drop shall not exceed ___ PSIG. 2 3 4 5 3 3
Creep shall not increase by more that ___ PSI in ___ minutes. 1,
5
1,
5
1,
5
1,
5
1,
5
1,
5

 

  VGS511
VGS510
VGS500
L3612C
S361C
S350C
L700A
L360A
L260A
L710A
S360A
S710A
S260A
L261A
S711C
L700C
S700C
S261C
S250C
L700B
S350B
S700B
S250B
AR350
AR154
AR153
AR151
S261D
S250D
S711D
L700D
S700D
L350D
L361D
S361D
S350D
L250D
CF253
AF250
HRF2380 HVTS2537
HVTS2570
HVTS2535
HVTS2559
HVTS2532
HVTS2533
HVTS2531
HVTS2530
HVTS2521
HRF2325
HSR2537
HSR2570
HSR2535
HSR2569
HSR2532
HSR2533
HSR2531
HSR2530
HSR2521
Test gun orifice size. #52
(.0635")
#52
(.0635")
#52
(.0635")
N/A #70
(.028")
#70
(.028")
Set regulator to ___ PSIG. 10 10 20 20 CFH 80 20
Drop shall not exceed ___ PSIG. 3 4 5 1.5 CFH 10 5
Creep shall not increase by more that ___ PSI in ___ minutes. 2,
5
2,
5
2.5,
5
0.5 CFH,
5
1,
5
1,
5

 

  SR3BF SR3BG SR3BJ SR5B SR6B SR7 SR13
SR12
SR11
SR10
Test gun orifice size. #55
(.0520")
#55
(.0520")
#55
(.0520")
#70
(.028")
#70
(.028")
#70
(.028")
#55
(.0520")
Set regulator to ___ PSIG. 250 500 1000 20 5 5 125
Drop shall not exceed ___ PSIG. 50 100 200 4 3 4 50
Creep shall not increase by more that ___ PSI in ___ minutes. 0,
5
0,
5
0,
5
4,
1
2,
5
2,
5
25,
5

CAUTION: Welding apparatus that is improperly maintained or repaired can be dangerous.  Some parts and accessories from one manufacturer may fit apparatus from other manufacturers, but the assembly may not conform to the standards of either manufacturer.  For your own safety, specify and use parts and attachments from only one manufacturer in any assembly according to that manufacturer's specifications.

Service and repair of welding apparatus should be performed only by a qualified repair technician.  Improper service or repair, or modification of a product could result in damage to the product or injury to the operator.

DISCLAIMER
Information contained herein is offered without charge for use by technically qualified personnel at their discretion and risk. All statements, technical information and recommendations contained herein are based on tests and data which we believe to be reliable, but the accuracy or completeness thereof Is not guaranteed and no warranty of any kind Is made with respect thereto. This Information Is not Intended as a license to operate under or a recommendation to practice or Infringe any patent of Argyle Welding Supply or others covering any process, composition of matter or use. Since Argyle Welding Supply shall have no control of the use of the information described herein, Argyle Welding Supply assumes no liability for loss, damage, or personal injury Incurred from the proper or Improper use of such product.